[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: HTTPAPI is returning an error message
Title: Message
Antoine,
This
is not a problem with httpapi, its to do with your iSeries connection to the
Internet.
There
could be many reasons.
First
try the PING (which you say also fails).
Here
is mine:
PING
RMTSYS(WWW.SCOTTKLEMENT.COM)
Verifying connection to host system WWW.SCOTTKLEMENT.COM at addre
206.55.70.27.
PING reply 1 from 206.55.70.27 took 225 ms. 256 bytes. TTL 233.
PING reply 2 from 206.55.70.27 took 272 ms. 256 bytes. TTL 233.
PING reply 3 from 206.55.70.27 took 171 ms. 256 bytes. TTL 233.
PING reply 4 from 206.55.70.27 took 170 ms. 256 bytes. TTL 233.
PING reply 5 from 206.55.70.27 took 174 ms. 256 bytes. TTL 233.
Round-trip (in milliseconds) min/avg/max =
170/202/272
Connection verification statistics: 5 of 5 successful (100 %).
If
this fails, try Scotts IP address (see above)
This
is mine:
PING
RMTSYS('206.55.70.27')
Verifying connection to host system
206.55.70.27.
PING reply 1 from 206.55.70.27 took 400 ms. 256 bytes. TTL
233.
PING reply 2 from 206.55.70.27 took 175 ms. 256
bytes. TTL 233.
PING reply 3 from 206.55.70.27 took 171
ms. 256 bytes. TTL 233.
PING reply 4 from 206.55.70.27
took 173 ms. 256 bytes. TTL 233.
PING reply 5 from
206.55.70.27 took 172 ms. 256 bytes. TTL 233.
Round-trip
(in milliseconds) min/avg/max =
171/218/400
Connection verification statistics: 5 of 5 successful (100
%).
If the
website address PING fails, but the IP address works, you have a DNS
problem.
You
can get round that by putting an entry into the host table for Scots website
& its IP address. (CFGTCP option 10)
If the
ping to the IP address fails, it looks like your iSeries is not connecting to
the Internet.
Possible reasons are:
No
connection at all
Connection goes through a proxy server that is rejecting traffic from the
iSeries
No
routing entries from the iSeries to your external Internet router. - (check
routing entries CFGTCP option 2)
Regards
Ian Patterson
Hi
I tried one of your example 15 program
from the AS/400 command line and it throws me an saying
"Timeout occurred while trying to connect
to server! "
I have increase the TIME wait to 100
seconds, but still the problem persist.
I am helpless now. Could
you please provide me step by step instruction to understand the problem and
overcome the same.
Thanks in
advance,
Regards
Antoine
The information contained in
this electronic message and any attachments to this message are intended
for the exclusive use of the addressee(s) and may contain proprietary,
confidential or privileged information. If you are not the intended
recipient, you should not disseminate, distribute or copy this e-mail.
Please notify the sender immediately and destroy all copies of this
message and any attachments.
WARNING: Computer viruses can be
transmitted via email. The recipient should check this email and any
attachments for the presence of viruses. The company accepts no
liability for any damage caused by any virus transmitted by this
email.
www.wipro.com
|